Package armyc2.c2sd.renderer.utilities
Class ModifiersUnits
java.lang.Object
armyc2.c2sd.renderer.utilities.ModifiersUnits
This class contains keys to the modifiers. A number of these we feed off of
the symbol code instead of using the property. But those modifiers remain
for completeness.
U = units, E = equipment, I= installations, SI = signals intelligence (SIGINT), SO = stability operations, EU = EMS units, EEI = EMS equipment and incidents, EI =
EMS installations.
-
Field Summary
FieldsModifier and TypeFieldDescriptionstatic final intThe innermost part of a symbol that represents a warfighting object Here for completeness, not actually used as this comes from the symbol code.static final intA text modifier for units; indicator is contained inside the frame (see figures 2 and 3); contains the name of the special C2 Headquarters.static final intFeint or dummy indicator: A graphic modifier for units, equipment, and installations that identifies an offensive or defensive unit intended to draw the enemy’s attention away from the area of the main attack (see 5.3.4.7 and figures 2 and 3).static final intInstallation: A graphic modifier for units, equipment, and installations used to show that a particular symbol denotes an installation (see 5.3.4.5 and figures 2 and 3).static final intELNOT or CENOT Type: SI Length: 6static final intEquipment teardown time in minutes.static final intExample: “Hawk� for Hawk SAM system.static final intTowed sonar array indicator: A graphic modifier for equipment that indicates the presence of a towed sonar array (see 5.3.4.4, figures 2 and 3, and table VII).static final intA graphic modifier for units and equipment that indicates the area where an object is most likely to be, based on the object’s last report and the reporting accuracy of the sensor that detected the object (see 5.3.4.11.1 and figure 4).static final intA graphic modifier for units and equipment that identifies where an object should be located at present, given its last reported course and speed (see 5.3.4.11.2 and figure 4).static final intA graphic modifier for units and equipment that depicts the speed and direction of movement of an object (see 5.3.4.11.3 and figure 4).static final intA graphic modifier for units and equipment that connects two objects and is updated dynamically as the positions of the objects change (see 5.3.4.11.4 and figure 4).static final intAn optional graphic modifier for equipment or installations that indicates operational condition or capacity.static final intA graphic amplifier placed immediately atop the symbol.static final intA graphic modifier in a unit symbol that identifies command level We feed off of the symbol code so this isn't used Type: U,SO Length: Gstatic final intA text modifier in an equipment symbol that identifies the number of items present.static final intPulled from the SymbolID.static final intA generic name label that goes to the right of the symbol and any existing labels.static final intA graphic modifier that identifies a unit or SO symbol as a task force (see 5.3.4.6 and figures 2 and 3).static final intA graphic modifier that displays standard identity, battle dimension, or exercise amplifying descriptors of an object (see 5.3.1 and table II).static final intA text modifier in a unit symbol that displays (+) for reinforced, (-) for reduced,(+) reinforced and reduced.static final intA text modifier for units, equipment and installations; content is implementation specific.static final intText modifier for amplifying free text Type: U,E,I,SI,SO,EU,EEI,EI Length: 20static final intText modifier for amplifying free text Type: U,E,I,SI,SO,EU,EEI,EI Length: 20static final intText modifier for amplifying free text Type: U,E,I,SI,SO,EU,EEI,EI Length: 20static final intA text modifier for units, equipment, and installations that consists of a one letter reliability rating and a one-number credibility rating.static final intA text modifier for units and installations that indicates unit effectiveness or installation capability.static final intA text modifier for hostile equipment; “!� indicates detectable electronic signatures.static final intA text modifier for units that indicates number or title of higher echelon command (corps are designated by Roman numerals).static final intA text modifier for equipment; letters "ENY" denote hostile symbols.static final intA text modifier displaying IFF/SIF Identification modes and codes.static final intA graphic modifier for units and equipment that identifies the direction of movement or intended movement of an object (see 5.3.4.1 and figures 2 and 3).static final intA graphic modifier for equipment that depicts the mobility of an object (see 5.3.4.3, figures 2 and 3, and table VI).static final intM = Mobile, S = Static, or U = Uncertain.static final intHeadquarters staff indicator: A graphic modifier for units, equipment, and installations that identifies a unit as a headquarters (see 5.3.4.8 and figures 2 and 3).static final intSonar Classification Confidence level.static final intA text modifier for units, equipment, and installations that uniquely identifies a particular symbol or track number.static final intA text modifier for units, equipment, and installations that uniquely identifies a particular symbol or track number.static final intA text modifier for equipment that indicates types of equipment.static final intA text modifier for units, equipment, and installations that displays DTG format: DDHHMMSSZMONYYYY or “O/O� for on order (see 5.5.2.6).static final intA text modifier for units, equipment, and installations that displays DTG format: DDHHMMSSZMONYYYY or “O/O� for on order (see 5.5.2.6).static final intA text modifier for units, equipment, and installations, that displays either altitude flight level, depth for submerged objects; or height of equipment or structures on the ground.static final intA text modifier for units, equipment, and installations that displays a symbol’s location in degrees, minutes, and seconds (or in UTM or other applicable display format).static final intA text modifier for units and equipment that displays velocity as set forth in MIL-STD-6040. -
Constructor Summary
Constructors -
Method Summary
Modifier and TypeMethodDescriptionstatic intgetModifierKey(String modLetter) go from "T" or "T1" to integer constant values 9 and 10static StringgetModifierLetterCode(int modifier) Returns an Arraylist of the modifer names for unitsstatic StringgetModifierName(int modifier)
-
Field Details
-
A_SYMBOL_ICON
The innermost part of a symbol that represents a warfighting object Here for completeness, not actually used as this comes from the symbol code. Type: U,E,I,SI,SO,EU,EEI,EI Length: G- See Also:
-
B_ECHELON
A graphic modifier in a unit symbol that identifies command level We feed off of the symbol code so this isn't used Type: U,SO Length: G- See Also:
-
C_QUANTITY
A text modifier in an equipment symbol that identifies the number of items present. Type: E,EEI Length: 9- See Also:
-
D_TASK_FORCE_INDICATOR
A graphic modifier that identifies a unit or SO symbol as a task force (see 5.3.4.6 and figures 2 and 3). Type: U,SO Length: G- See Also:
-
E_FRAME_SHAPE_MODIFIER
A graphic modifier that displays standard identity, battle dimension, or exercise amplifying descriptors of an object (see 5.3.1 and table II). Type: U,E,I,SO,EU,EEI,EI Length: G- See Also:
-
F_REINFORCED_REDUCED
A text modifier in a unit symbol that displays (+) for reinforced, (-) for reduced,(+) reinforced and reduced. R = reinforced,D = reduced,RD = reinforced and reduced Type: U,SO Length: 23- See Also:
-
G_STAFF_COMMENTS
A text modifier for units, equipment and installations; content is implementation specific. Type: U,E,I,SI,SO Length: 20- See Also:
-
H_ADDITIONAL_INFO_1
Text modifier for amplifying free text Type: U,E,I,SI,SO,EU,EEI,EI Length: 20- See Also:
-
H1_ADDITIONAL_INFO_2
Text modifier for amplifying free text Type: U,E,I,SI,SO,EU,EEI,EI Length: 20- See Also:
-
H2_ADDITIONAL_INFO_3
Text modifier for amplifying free text Type: U,E,I,SI,SO,EU,EEI,EI Length: 20- See Also:
-
J_EVALUATION_RATING
A text modifier for units, equipment, and installations that consists of a one letter reliability rating and a one-number credibility rating. Reliability Ratings: A-completely reliable, B-usually reliable, C-fairly reliable, D-not usually reliable, E-unreliable, F-reliability cannot be judged. Credibility Ratings: 1-confirmed by other sources, 2-probably true, 3-possibly true, 4-doubtfully true, 5-improbable, 6-truth cannot be judged. Type: U,E,I,SI,SO,EU,EEI,EI Length: 2- See Also:
-
K_COMBAT_EFFECTIVENESS
A text modifier for units and installations that indicates unit effectiveness or installation capability. Type: U,I,SO Length: 5,5,3- See Also:
-
L_SIGNATURE_EQUIP
A text modifier for hostile equipment; “!� indicates detectable electronic signatures. Type: E,SI Length: 1- See Also:
-
M_HIGHER_FORMATION
A text modifier for units that indicates number or title of higher echelon command (corps are designated by Roman numerals). Type: U,SI Length: 21- See Also:
-
N_HOSTILE
A text modifier for equipment; letters "ENY" denote hostile symbols. Type: E Length: 3- See Also:
-
P_IFF_SIF
A text modifier displaying IFF/SIF Identification modes and codes. Type: U,E,SO Length: 5- See Also:
-
Q_DIRECTION_OF_MOVEMENT
A graphic modifier for units and equipment that identifies the direction of movement or intended movement of an object (see 5.3.4.1 and figures 2 and 3). Type: U,E,SO,EU,EEI Length: G- See Also:
-
R_MOBILITY_INDICATOR
A graphic modifier for equipment that depicts the mobility of an object (see 5.3.4.3, figures 2 and 3, and table VI). We feed off of the symbol code for mobility so this isn't used Type: E,EEI Length: G- See Also:
-
R2_SIGNIT_MOBILITY_INDICATOR
M = Mobile, S = Static, or U = Uncertain. Type: SI Length: 1- See Also:
-
S_HQ_STAFF_OR_OFFSET_INDICATOR
Headquarters staff indicator: A graphic modifier for units, equipment, and installations that identifies a unit as a headquarters (see 5.3.4.8 and figures 2 and 3). Offset location indicator: A graphic modifier for units, equipment, and installations used when placing an object away from its actual location (see 5.3.4.9 and figures 2 and 3). Type: U,E,I,SO,EU,EEI,EI Length: G- See Also:
-
T_UNIQUE_DESIGNATION_1
A text modifier for units, equipment, and installations that uniquely identifies a particular symbol or track number. Identifies acquisitions number when used with SIGINT symbology. Type: U,E,I,SI,SO,EU,EEI,EI Length: 21- See Also:
-
T1_UNIQUE_DESIGNATION_2
A text modifier for units, equipment, and installations that uniquely identifies a particular symbol or track number. Identifies acquisitions number when used with SIGINT symbology. Type: U,E,I,SI,SO,EU,EEI,EI Length: 21- See Also:
-
V_EQUIP_TYPE
A text modifier for equipment that indicates types of equipment. For Tactical Graphics: A text modifier that indicates nuclear weapon type. Type: E,SI,EEI Length: 24- See Also:
-
W_DTG_1
A text modifier for units, equipment, and installations that displays DTG format: DDHHMMSSZMONYYYY or “O/O� for on order (see 5.5.2.6). Type: U,E,I,SI,SO,EU,EEI,EI Length: 16- See Also:
-
W1_DTG_2
A text modifier for units, equipment, and installations that displays DTG format: DDHHMMSSZMONYYYY or “O/O� for on order (see 5.5.2.6). Type: U,E,I,SI,SO,EU,EEI,EI Length: 16- See Also:
-
X_ALTITUDE_DEPTH
A text modifier for units, equipment, and installations, that displays either altitude flight level, depth for submerged objects; or height of equipment or structures on the ground. See 5.5.2.5 for content. Type: U,E,I,SO,EU,EEI,EI Length: 14- See Also:
-
Y_LOCATION
A text modifier for units, equipment, and installations that displays a symbol’s location in degrees, minutes, and seconds (or in UTM or other applicable display format). Conforms to decimal degrees format: xx.dddddhyyy.dddddh where xx = degrees latitude yyy = degrees longitude .ddddd = decimal degrees h = direction (N, E, S, W) Type: U,E,I,SI,SO,EU,EEI,EI Length: 19- See Also:
-
Z_SPEED
A text modifier for units and equipment that displays velocity as set forth in MIL-STD-6040. Type: U,E,SO,EU,EEI Length: 8- See Also:
-
AA_SPECIAL_C2_HQ
A text modifier for units; indicator is contained inside the frame (see figures 2 and 3); contains the name of the special C2 Headquarters. Type: U,SO Length: 9- See Also:
-
AB_FEINT_DUMMY_INDICATOR
Feint or dummy indicator: A graphic modifier for units, equipment, and installations that identifies an offensive or defensive unit intended to draw the enemy’s attention away from the area of the main attack (see 5.3.4.7 and figures 2 and 3). Type: U,E,I,SO Length: G- See Also:
-
AC_INSTALLATION
Installation: A graphic modifier for units, equipment, and installations used to show that a particular symbol denotes an installation (see 5.3.4.5 and figures 2 and 3). Not used, we feed off of symbol code for this Type: U,E,I,SO,EU,EEI,EI Length: G- See Also:
-
AD_PLATFORM_TYPE
ELNOT or CENOT Type: SI Length: 6- See Also:
-
AE_EQUIPMENT_TEARDOWN_TIME
Equipment teardown time in minutes. Type: SI Length: 3- See Also:
-
AF_COMMON_IDENTIFIER
Example: “Hawk� for Hawk SAM system. Type: SI Length: 12- See Also:
-
AG_AUX_EQUIP_INDICATOR
Towed sonar array indicator: A graphic modifier for equipment that indicates the presence of a towed sonar array (see 5.3.4.4, figures 2 and 3, and table VII). Type: E Length: G- See Also:
-
AH_AREA_OF_UNCERTAINTY
A graphic modifier for units and equipment that indicates the area where an object is most likely to be, based on the object’s last report and the reporting accuracy of the sensor that detected the object (see 5.3.4.11.1 and figure 4). Type: E,U,SO,EU,EEI Length: G- See Also:
-
AI_DEAD_RECKONING_TRAILER
A graphic modifier for units and equipment that identifies where an object should be located at present, given its last reported course and speed (see 5.3.4.11.2 and figure 4). Type: E,U,SO,EU,EEI Length: G- See Also:
-
AJ_SPEED_LEADER
A graphic modifier for units and equipment that depicts the speed and direction of movement of an object (see 5.3.4.11.3 and figure 4). Type: E,U,SO,EU,EEI Length: G- See Also:
-
AK_PAIRING_LINE
A graphic modifier for units and equipment that connects two objects and is updated dynamically as the positions of the objects change (see 5.3.4.11.4 and figure 4). Type: U,E,SO Length: G- See Also:
-
AL_OPERATIONAL_CONDITION
An optional graphic modifier for equipment or installations that indicates operational condition or capacity. Type: E,I,SI,SO,EU,EEI,EI Length: G- See Also:
-
AO_ENGAGEMENT_BAR
A graphic amplifier placed immediately atop the symbol. May denote, 1) local/remote status; 2) engagement status; and 3) weapon type. Type: U,E,I Length: G/8- See Also:
-
CC_COUNTRY_CODE
Pulled from the SymbolID. Not something the user should set directly.- See Also:
-
SCC_SONAR_CLASSIFICATION_CONFIDENCE
Sonar Classification Confidence level. valid values are 1-5. Only applies to the 4 subsurface MILCO sea mines- See Also:
-
CN_CPOF_NAME_LABEL
A generic name label that goes to the right of the symbol and any existing labels. If there are no existing labels, it goes right next to the right side of the symbol. This is a CPOF label that applies to all force elements. This IS NOT a MilStd or USAS Label.- See Also:
-
-
Constructor Details
-
ModifiersUnits
public ModifiersUnits()
-
-
Method Details
-
GetModifierList
Returns an Arraylist of the modifer names for units- Returns:
-
getModifierName
- Parameters:
modifier- like ModifiersTG.C_QUANTITY- Returns:
- modifier name based on mofidier constants
-
getModifierLetterCode
- Parameters:
modifier- like ModifiersUnits.C_QUANTITY- Returns:
- modifier name based on mofidier constants
-
getModifierKey
go from "T" or "T1" to integer constant values 9 and 10- Parameters:
modLetter-- Returns:
-